Eranium Logo

Nikhef Patch Calculator

This tool allows you to easily calculate the appropriate length for the cross-connect required.

Eager to get your ERA-IX port live?

We woke up feeling good and felt like being nice, so we've allowed calculation of distance between any two racks 😉

Fill in or click on the A and Z side racks of your intended cross-connect and let the program do the rest.
Please take notice of the spare on each side and where you need to be in each rack for the best results.
You will also be presented with a suggested trajectory for the cross-connect.

Show me an example


Please select your A-side.
Looks good!
Please select your Z-side.
Looks good!
Looks good!

H140 Floorplan

44
45
46
47
48
51
52
53
55
39
40
41
42
43
54
56
57
58
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
30
35
36
37
38
59
60
63
95
26
27
28
32
34
61
62
96
97
25
24
23
22
21
20
19
18
17
16
15
14
366
365
364
316
317
318
319
320
321
322
323
324
74
73
72
71
70
69
68
67
66
65
64
29
302
303
304
301
325
326
327
328
329
330
331
332
333
85
84
83
82
81
80
79
78
77
76
75
305
306
307
308
334
335
336
337
338
339
340
94
93
92
91
90
98
99
89
88
87
86
309
310
311
312
341
342
343
344
345
346
347
348
349
149
150
151
152
153
154
155
1387
372
373
374
204
203
202
201
200
1
2
3
4
5
6
7
8
206
205
313
314
315
367
350
351
352
353
354
355
356
100
156
157
158
159
160
161
162
163
164
165
368
357
358
359
360
361
362
363
199
166
167
168
169
170
171
172
173
174
207
208
209
210
211
212
213
375
369
175
176
177
178
179
180
181
182
183
184
185
186
187
188
370
189
190
191
192
193
194
195
196
197
198

Using the calculator

Inputs

Source Rack
Commonly called the A-side for the cross-connect.
Destination Rack
Commonly called the Z-side for the cross-connect.
Spare
How much fiber should (at least) be left on each side, given in centimeters.

Instructions

Fill in your own rack number in the Source Rack field, fill in the remote rack (you will be provided this rack through a LOA) in the Destination rack. Continue by checking if the spare length will get you where you need to be in the rack.
Once filled in, click on Compute Length, the tool will perform the calculations necessary to ensure you get the correct fiber on the first try! Results are rounded up to the nearest 5M increment. On the floorplan the calculator will also display a suggested route.
Alternatively, you are also able to enter the racks by clicking on them in the floorplan.

Eager to learn more?

Check out these posts on LinkedIn: ERA-IX - Development Update Elias - Technical Details (Dutch)

About NIKHEF Housing

NIKHEF Housing provides a great environments for networks to establish themselves and through the availability of over 300 other networks address their interconnection needs.
For this reason ERA-IX was initially launched within the facility. NIKHEF Housing is located in the Science Park in Amsterdam, in close vicinity to other datacenters such as Interxion AMS9, AMS17 and Equinix AM3, AM4. So close in fact that you should be able to order cross connects from them towards NIKHEF Housing.

Installing cross-connects

In NIKHEF Housing, customers are free to install their own cross connects. Free of charge, this is a big advantage compared to their neighbors 😄.
When installing cross-connects please follow instructions provided by staff and adhere to the Nikhef Housing Cabling Guidelines

When installing a cross-connect to ERA-IX, your patch will be connected on the hot side of our rack. Your fiber must go down the spillway to enter the rack, be routed through the cable loops on the right of the rack and enter the pre-cabling from the right.